Time Synchronization Source Failover


In real-world deployments, redundancy and recovery mechanisms are critical to maintaining accurate time synchronization if one of the time synchronization sources fails.
This test is designed to measure any changes in the time error at the output of each Telecom Boundary Clock when the primary Telecom Grandmaster (T-GM) fails, and a switch to the secondary T-GM occurs.

Figure 95

Figure 95: Time Synchronization Source Failover - Test bed setup of both test runs

Two separate Microchip TimeProvider 4500 units were used as T-GM-A and T-GM-B, with all T-BCs being directly connected to both T-GMs. T-GM-A acted as the primary Grandmaster, as each Boundary Clock was configured with local priorities to prefer and lock to T-GM-A for both PTP and SyncE.
We disconnected the GNSS from T-GM-A, causing the BCs to switch to T-GM-B. After measuring for 1000s, including the failover, the measurement was restarted, and the GNSS connection to GM-A was reestablished, with all T-BCs locking back to T-GM-A on PTP and SyncE. The Calnex Paragon neo, Paragon neo-A, and the Keysight Time Sync Analyzer were used to measure the PTP and SyncE output of all the T-BCs.
We executed two separate test runs with different T-BCs but using the same procedure.
For both runs, the two-way time error for all devices was within the class-level accuracy limit of 6C (±65 ns), as per ITU-T G.8271, throughout the failover from T-GM-A to T-GM-B and the switchover back from T-GM-B to T-GM-A. For the MTIE, all devices were well within the threshold of the “Holdover Performance Const. Temp. T-BC/T-TSC Class A/B”, as specified in ITU-T G.8273.2, Table 7-10/Figure 7-1.

Telecom GrandmastersTelecom Boundary ClocksFrequency/Phase Analyzers
Microchip Time Provider 4500 (T-GM-A),
Microchip Time Provider 4500 (T-GM-B)
HPE MX304,
Cisco 8011-4G24Y4H-I,
Ericsson RAN Connect 6682,
ZTE ZXCTN 6120H-S,
Ciena 5164,
Raisecom iTN8800-A,
HPE ACX7024,
Microchip Time Provider 4500,
ZTE ZXR10 M6000-4SE,
Ericsson Router 6676
Calnex Paragon neo,
Calnex Paragon neo-A,
Keysight Time Sync Analyzer

Table 75: Time Synchronization Source Failover - Devices under Test

Interested in our testing services?

If you are interested and would like to receive more information, please send us an email and sign up for our newsletter to stay up-to-date.