1 |
(% class="row" %) |
|
|
2 |
((( |
|
|
3 |
(% class="col-xs-12 col-sm-8 test-report-content" %) |
|
|
4 |
((( |
|
|
5 |
---- |
|
|
6 |
|
|
|
7 |
Class C and D Telecom Boundary Clocks (T-BCs) are essential for meeting the tight time-synchronization requirements of today’s highly time-sensitive networks, such as 5G. |
|
|
8 |
ITU-T G.8273.2 defines several metrics and clear requirements for class C T-BC clocks. In contrast, for Class D, only one requirement is currently specified in ITU-T G.8273.2, section 7.1, table 7-2: a low-pass filtered maximum absolute time error (max|TE,,L,,| ≤ 5 ns). |
|
|
9 |
The performance of devices tested this year has improved once again compared to previous years. |
|
|
10 |
Every T-BC tested remained well within the Class D performance limit (max|TE,,L,,| ≤ 5 ns). |
|
|
11 |
This year, few Class C Conformance tests were conducted because almost every device was already compliant with Class D Conformance, leaving little incentive to test for Class C Conformance. However, all devices that executed the Class C Conformance test were also compliant. |
|
|
12 |
|
|
|
13 |
[[~[~[Figure 89: Test setup for Class C/D Conformance Tests~>~>image:487250132039958529_conformance.png~|~|alt="Figure 89"~]~]>>attach:487250132039958529_conformance.png||target="_blank"]] |
|
|
14 |
|
|
|
15 |
Both test scenarios used an emulated Telecom Grandmaster (T-GM) and an emulated Telecom Time Synchronous Clock (T-TSC), both of which were either the Calnex Paragon neo, Calnex Paragon neo-A, Calnex Paragon neo-S, or the Keysight Time Sync Analyzer, with the T-BC under test positioned in between. These tests were conducted with either 10 or 100 Gigabit Ethernet (GbE) links, or, in two cases, even 800 GbE links. |
|
|
16 |
Although these were not interoperability tests, they were crucial because the clocks had to achieve either class C or class D qualification before being allowed to participate in further testing. |
|
|
17 |
|
|
|
18 |
{{container cssClass="tc-role-table"}} |
|
|
19 |
(% class="table-bordered" %) |
|
|
20 |
|=Emulated Telecom Grandmaster|=Telecom Boundary Clock under Test|=Emulated Telecom Time Synchronous Clock & Frequency/Phase Analyzer |
|
|
21 |
|Calnex Paragon neo-A|ZTE ZXR10 M6000-2S16|Calnex Paragon neo-A |
|
|
22 |
|Calnex Paragon neo-A|ZTE ZXCTN 6120H-S|Calnex Paragon neo-A |
|
|
23 |
|Keysight Time Sync Analyzer|ZTE ZXCTN 6120H-E|Keysight Time Sync Analyzer |
|
|
24 |
|Calnex Paragon neo-A|ZTE ZXR10 M6000-4SE|Calnex Paragon neo-A |
|
|
25 |
|Keysight Time Sync Analyzer|HPE ACX 7020|Keysight Time Sync Analyzer |
|
|
26 |
|Keysight Time Sync Analyzer|HPE ACX 7024|Keysight Time Sync Analyzer |
|
|
27 |
|Calnex Paragon neo|HPE ACX 7332|Calnex Paragon neo |
|
|
28 |
|Calnex Paragon neo|HPE MX 304|Calnex Paragon neo |
|
|
29 |
|Keysight Time Sync Analyzer|Ericsson Router 6671|Keysight Time Sync Analyzer |
|
|
30 |
|Calnex Paragon neo|Ericsson Router 6676|Calnex Paragon neo |
|
|
31 |
|Calnex Paragon neo|Ericsson RAN Connect 6682|Calnex Paragon neo |
|
|
32 |
|Keysight Time Sync Analyzer|Ciena 5164|Keysight Time Sync Analyzer |
|
|
33 |
|Keysight Time Sync Analyzer|Microchip Time Provider 4500|Keysight Time Sync Analyzer |
|
|
34 |
|Calnex Paragon neo-A|Cisco 8011-4G24Y4H-I|Calnex Paragon neo-A |
|
|
35 |
|Calnex Paragon neo|Raisecom iTN8800-A|Calnex Paragon neo |
|
|
36 |
|Keysight Time Sync Analyzer|ZTE ZXR10 M6000-3S Plus|Keysight Time Sync Analyzer |
|
|
37 |
|Keysight Time Sync Analyzer|HPE PTX10002-60MR|Keysight Time Sync Analyzer |
|
|
38 |
|Keysight Time Sync Analyzer|HPE PTX10002-36QDD|Keysight Time Sync Analyzer |
|
|
39 |
|
|
|
40 |
{{/container}} |
|
|
41 |
|
|
|
42 |
Table 62: ITU-T G.8273.2 - Telecom Boundary Clock Class D Conformance - 10 GbE |
|
|
43 |
|
|
|
44 |
{{container cssClass="tc-role-table"}} |
|
|
45 |
(% class="table-bordered" %) |
|
|
46 |
|=Emulated Telecom Grandmaster|=Telecom Boundary Clock under Test|=Emulated Telecom Time Synchronous Clock & Frequency/Phase Analyzer |
|
|
47 |
|Calnex Paragon neo-A|HPE PTX10002-60MR|Calnex Paragon neo-A |
|
|
48 |
|Calnex Paragon neo-A|HPE ACX 7100-32C|Calnex Paragon neo-A |
|
|
49 |
|Calnex Paragon neo-A|HPE PTX10002-36QDD|Calnex Paragon neo-A |
|
|
50 |
|Calnex Paragon neo|Cisco 8711-32FH-M|Calnex Paragon neo |
|
|
51 |
|Keysight Time Sync Analyzer|Cisco 8011-4G24Y4H-I|Keysight Time Sync Analyzer |
|
|
52 |
|Keysight Time Sync Analyzer|Ciena 5164|Keysight Time Sync Analyzer |
|
|
53 |
|Keysight Time Sync Analyzer|Ericsson RAN Connect 6682|Keysight Time Sync Analyzer |
|
|
54 |
|Calnex Paragon neo-A|HPE ACX 7332|Calnex Paragon neo-A |
|
|
55 |
|Calnex Paragon neo-A|HPE MX 304|Calnex Paragon neo-A |
|
|
56 |
|Calnex Paragon neo-A|HPE ACX 7024|Calnex Paragon neo-A |
|
|
57 |
|Calnex Paragon neo-A|HPE MX 301|Calnex Paragon neo-A |
|
|
58 |
|Keysight Time Sync Analyzer|Cisco Nexus C93400LD-H1|Keysight Time Sync Analyzer |
|
|
59 |
|
|
|
60 |
{{/container}} |
|
|
61 |
|
|
|
62 |
Table 63: ITU-T G.8273.2 - Telecom Boundary Clock Class D Conformance - 100 GbE |
|
|
63 |
|
|
|
64 |
{{container cssClass="tc-role-table"}} |
|
|
65 |
(% class="table-bordered" %) |
|
|
66 |
|=Emulated Telecom Grandmaster|=Telecom Boundary Clock under Test|=Emulated Telecom Time Synchronous Clock & Frequency/Phase Analyzer |
|
|
67 |
|Calnex Paragon neo-S|Ciena 8192|Calnex Paragon neo-S |
|
|
68 |
|Calnex Paragon neo-S|HPE PTX10002-60MR|Calnex Paragon neo-S |
|
|
69 |
|
|
|
70 |
{{/container}} |
|
|
71 |
|
|
|
72 |
Table 64: ITU-T G.8273.2 - Telecom Boundary Clock Class D Conformance - 800 GbE |
|
|
73 |
|
|
|
74 |
{{container cssClass="tc-role-table"}} |
|
|
75 |
(% class="table-bordered" %) |
|
|
76 |
|=Emulated Telecom Grandmaster|=Telecom Boundary Clock under Test|=Emulated Telecom Time Synchronous Clock & Frequency/Phase Analyzer |
|
|
77 |
|Keysight Time Sync Analyzer|Raisecom iTN8800-A|Keysight Time Sync Analyzer |
|
|
78 |
|Keysight Time Sync Analyzer|Microchip Time Provider 4500|Keysight Time Sync Analyzer |
|
|
79 |
|Keysight Time Sync Analyzer|ZTE ZXCTN 6120H-S|Keysight Time Sync Analyzer |
|
|
80 |
|Keysight Time Sync Analyzer|ZTE ZXCTN 6120H-E|Keysight Time Sync Analyzer |
|
|
81 |
|Keysight Time Sync Analyzer|ZTE ZXR10 M6000-4SE|Keysight Time Sync Analyzer |
|
|
82 |
|Keysight Time Sync Analyzer|ZTE ZXR10 M6000-3S Plus|Keysight Time Sync Analyzer |
|
|
83 |
|
|
|
84 |
{{/container}} |
|
|
85 |
|
|
|
86 |
Table 65: ITU-T G.8273.2 - Telecom Boundary Clock Class C Conformance - 10 GbE |
|
|
87 |
|
|
|
88 |
{{container cssClass="tc-role-table"}} |
|
|
89 |
(% class="table-bordered" %) |
|
|
90 |
|=Emulated Telecom Grandmaster|=Telecom Boundary Clock under Test|=Emulated Telecom Time Synchronous Clock & Frequency/Phase Analyzer |
|
|
91 |
|Keysight Time Sync Analyzer|Ciena 5164|Keysight Time Sync Analyzer |
|
|
92 |
|Keysight Time Sync Analyzer|Cisco Nexus 93180YC-FX3|Keysight Time Sync Analyzer |
|
|
93 |
|
|
|
94 |
{{/container}} |
|
|
95 |
|
|
|
96 |
Table 66: ITU-T G.8273.2 - Telecom Boundary Clock Class C Conformance - 100 GbE |
|
|
97 |
|
|
|
98 |
(% id="prev-next-links" %) |
|
|
99 |
|[[< Previous>>doc:Main.EANTC Transport & Cloud Networks Interop Test Report 2026.Time Synchronization.WebHome]]|[[Next ~>>>doc:PTP over MACsec]] |
|
|
100 |
))) |
|
|
101 |
|
|
|
102 |
(% class="col-xs-12 col-sm-4 test-report-sidebar" %) |
|
|
103 |
((( |
|
|
104 |
{{box}} |
|
|
105 |
{{include reference="Main.EANTC Transport & Cloud Networks Interop Test Report 2026.Sidebar Nav"/}} |
|
|
106 |
{{/box}} |
|
|
107 |
))) |
|
|
108 |
))) |