Resilience scenarios have always been a key focus of our annual testing event, designed to simulate network failures to validate the performance of PTP (Precision Time Protocol) during a source loss. |
|
|
8 |
This test case evaluates the ability of boundary clocks to maintain acceptable time error during the loss of the Telecom Grandmaster (T-GM) as the PTP reference. |
|
|
9 |
When the T-GM becomes unavailable, boundary clocks enter holdover mode while remaining locked to the SyncE frequency reference from the T-GM. |
|
|
10 |
The goal is to evaluate the holdover performance of each individual Telecom Boundary Clock (T-BC) to ensure stable time synchronization and minimal drift without the primary time reference. |
|
|
11 |
|
|
|
12 |
Microchip participated in this test with TimeProvider® 4500 as the Telecom Grandmaster (T-GM), providing PTP and SyncE to each T-BC. A second TimeProvider® 4500 with a rubidium internal oscillator was used as the reference clock for the two measurement tools, the Calnex Paragon-Neo PAM4 and the Keysight Time Sync Analyzer. |
|
|
13 |
|
|
|
14 |
[[Figure 108: Multi-Telecom Boundary Clock Holdover Test - Setup>>image:434865443399073793_5.05-setup.png||alt="Figure 108" width="550"]] |
|
|
15 |
|
|
|
16 |
After all seven T-BCs were locked to the T-GM, Microchip configured the TimeProvider 4500 to advertise clock class 140, causing all the T-BCs to enter PTP holdover while still being locked on SyncE. |
|
|
17 |
The measurement was left running for 1 hour. Calnex and Keysight measured MTIE, with the MTIE per device ranging from 9.75 nanoseconds (ns) to 42.734ns, with six out of seven devices below the 13ns mark. |
|
|
18 |
All seven T-BCs were below the T-BC Class B holdover performance threshold at a constant temperature as defined in ITU-T G.8273.2, section 7.4.2.2, table 7-10/figure 7-1. |
|
|
19 |
|
|
|
20 |
[[Figure 109: MTIE measurement by Calnex Paragon-Neo PAM4>>image:434609235448299521_5.05-mtie-calnex.PNG||alt="Figure 109" width="550"]] |
|
|
21 |
|
|
|
22 |
[[Figure 110: MTIE measurement by Keysight Time Sync Analyzer>>image:434609243216150529_5.05-mtie-KS.png||alt="Figure 110" width="550"]] |
|
|
23 |
|
|
|
24 |
(% id="prev-next-links" %) |
|
|
25 |
|[[< Previous>>doc:PTP over DWDM transport]]|[[Next ~>>>doc:Holdover with Enhanced Sync-E Support]] |
|
|
26 |
))) |
|
|
27 |
|
|
|
28 |
(% class="col-xs-12 col-sm-5 test-report-sidebar" %) |
|
|
29 |
((( |
|
|
30 |
{{box}} |
|
|
31 |
{{include reference="Main.Multi-Vendor MPLS & SDN Interoperability Test Report 2025.Sidebar Nav"/}} |
|
|
32 |
{{/box}} |
|
|
33 |
))) |
|
|
34 |
))) |