6
7 Resilience scenarios have always been a key focus of our annual testing event, designed to simulate network failures to validate the performance of PTP (Precision Time Protocol) during a source loss.
8 This test case evaluates the ability of boundary clocks to maintain acceptable time error during the loss of the Telecom Grandmaster (T-GM) as the PTP reference.
9 When the T-GM becomes unavailable, boundary clocks enter holdover mode while remaining locked to the SyncE frequency reference from the T-GM.
10 The goal is to evaluate the holdover performance of each individual Telecom Boundary Clock (T-BC) to ensure stable time synchronization and minimal drift without the primary time reference.
11
12 Microchip participated in this test with TimeProvider® 4500 as the Telecom Grandmaster (T-GM), providing PTP and SyncE to each T-BC. A second TimeProvider® 4500 with a rubidium internal oscillator was used as the reference clock for the two measurement tools, the Calnex Paragon-Neo PAM4 and the Keysight Time Sync Analyzer.
13
14 [[Figure 108: Multi-Telecom Boundary Clock Holdover Test - Setup>>image:434865443399073793_5.05-setup.png||alt="Figure 108" width="550"]]
15
16 After all seven T-BCs were locked to the T-GM, Microchip configured the TimeProvider 4500 to advertise clock class 140, causing all the T-BCs to enter PTP holdover while still being locked on SyncE.
17 The measurement was left running for 1 hour. Calnex and Keysight measured MTIE, with the MTIE per device ranging from 9.75 nanoseconds (ns) to 42.734ns, with six out of seven devices below the 13ns mark.
18 All seven T-BCs were below the T-BC Class B holdover performance threshold at a constant temperature as defined in ITU-T G.8273.2, section 7.4.2.2, table 7-10/figure 7-1.
19
20 [[Figure 109: MTIE measurement by Calnex Paragon-Neo PAM4>>image:434609235448299521_5.05-mtie-calnex.PNG||alt="Figure 109" width="550"]]
21
22 [[Figure 110: MTIE measurement by Keysight Time Sync Analyzer>>image:434609243216150529_5.05-mtie-KS.png||alt="Figure 110" width="550"]]
23
24 (% id="prev-next-links" %)
25 |[[< Previous>>doc:PTP over DWDM transport]]|[[Next ~>>>doc:Holdover with Enhanced Sync-E Support]]
26 )))
27
28 (% class="col-xs-12 col-sm-5 test-report-sidebar" %)
29 (((
30 {{box}}
31 {{include reference="Main.Multi-Vendor MPLS & SDN Interoperability Test Report 2025.Sidebar Nav"/}}
32 {{/box}}
33 )))
34 )))